        <article-title>ПРЕДВАРИТЕЛЬНЫЕ МЕДИЦИНСКИЕ ИССЛЕДОВАНИЯ, ОСНОВАННЫЕ НА ЭЛЕКТРОКАРДИОГРАФЕ НА НАНОСЕНСОРАХ</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name-alternatives>
            <name xml:lang="ru">
              <surname>Турушев</surname>
              <given-names>Н.В.</given-names>
            </name>
          </name-alternatives>
          <name-alternatives>
            <name xml:lang="en">
              <surname>Turushev</surname>
              <given-names>N.V.</given-names>
            </name>
          </name-alternatives>
          <email>nvtur90@mail.ru</email>
          <xref ref-type="aff" rid="aff703fbccf"/>
        </contrib>
        <contrib contrib-type="author">
          <name-alternatives>
            <name xml:lang="ru">
              <surname>Григорьев</surname>
              <given-names>М.Г.</given-names>
            </name>
          </name-alternatives>
          <name-alternatives>
            <name xml:lang="en">
              <surname>Grigorev</surname>
              <given-names>M.G.</given-names>
            </name>
          </name-alternatives>
          <email>mishatpu@mail.ru</email>
          <xref ref-type="aff" rid="aff703fbccf"/>
        </contrib>
      </contrib-group>
      <aff id="aff703fbccf">
        <institution xml:lang="ru">ФГАОУ ВО «Национальный исследовательский Томский политехнический университет»</institution>
        <institution xml:lang="en">National research Tomsk polytechnic university</institution>
      </aff>
      <pub-date date-type="pub" iso-8601-date="2014-06-18">
        <day>18</day>
        <month>06</month>
        <year>2014</year>
      </pub-date>
      <issue>6</issue>
      <fpage>28</fpage>
      <lpage>28</lpage>
      <permissions>
        <license xlink:href="https://creativecommons.org/licenses/by/4.0/">
          <license-p>This is an open-access article distributed under the terms of the CC BY 4.0 license.</license-p>
        </license>
      </permissions>
      <self-uri content-type="url" hreflang="ru">https://science-education.ru/ru/article/view?id=15426</self-uri>
      <abstract xml:lang="ru" lang-variant="original" lang-source="author">
        <p>Прецизионные методы и приборы для диагностики сердечно – сосудистых заболеваний являются одними из основных направлений развития современной техники в области медицинского приборостроения. Однако на данном этапе развития не существует мало габаритных аппаратов, позволяющих проводить диагностику сердечной мышцы с прецизионной точностью и без внутреннего вмешательства в организм. В данном исследовании рассмотрены методы измерения биопотенциалов с поверхности тела человека при помощи электрокардиографических наносенсоров. Рассмотрен прибор, разрабатываемый в лаборатории №63 Института Неразрушающего Контроля Национального Исследовательского Томского Политехнического Университета, его параметры и основные характеристики. В статье акцентируется внимание на применении более чувствительного оборудования для более глубокого изучения человеческого организма. Приведены результаты проведённых измерений с помощью разработанного прибора.</p>
      </abstract>
      <abstract xml:lang="en" lang-variant="translation" lang-source="translator">
        <p>Precision methods and devices for the diagnostics of cardiovascular diseases are the one of the main directions of modern technology development in the field of medical instrument making. However, at this stage of development there are a few overall devices that allow for the diagnostics of cardiac muscle with precise accuracy and without internal interference in the body. This study considers the methods for measurement of biopotentials from the surface of the human body by means of electrocardiographic nanosensors. The device developed in the laboratory No. 63 of the Institute of Non-Destructive Testing of the National Research Tomsk Polytechnic University, its parameters and main characteristics are considered. The article focuses on the use of more sensitive equipment for more detailed study of the human body. The results of measurements carried out by means of the developed device are given.</p>
      </abstract>
      <kwd-group xml:lang="ru">
        <kwd>электрокардиограф</kwd>
        <kwd>электрокардиография</kwd>
        <kwd>биопотенциал</kwd>
        <kwd>медицинские приборы</kwd>
        <kwd>применение хлорсеребряных наносенсоров</kwd>
      </kwd-group>
      <kwd-group xml:lang="en">
        <kwd>electrocardiograph</kwd>
        <kwd>electrocardiography</kwd>
        <kwd>biopotential</kwd>
        <kwd>medical devices</kwd>
        <kwd>use of silver-chloride nanosensors</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <back>
    <ref-list>
      <ref>
        <note>
          <p>1.	Авдеева Д.К., Рыбалка С.А., Южаков М.М. Разработка метода измерения широкополосных сигналов нановольтового и микровольтового уровня для электрофизиологических исследований // Международный журнал прикладных и фундаментальных исследований. – 2012. – №11. – С. 37 – 38.</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>2.	Григорьев М. Г., Турушев Н. В. Моделирование электрической активности сердца // Современное состояние и проблемы естественных наук: сборник трудов всероссийской научно-практической конференции молодых ученых, аспирантов и студентов, (Юрга, 17 – 18 Апреля 2014г.). – Томск; 2014. – C. 317 – 320.</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>3.	Тарасенко Ф.П. Прикладной системный анализ: учебное пособие. М.: КноРус, 2010. – 224 с.</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>4.	Honq M. The Development of ECG and PPG Measurement Device // Applied Mechanics and Materials. – 2012. – No. 236/5.– pp. 1205 – 1210</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>5.	Nihon Kohden CardioFax cardiofax GEM // Med-electronics URL: http://www.med-electronics.com/Nihon-Kohden-CardioFax-cardiofax-GEM-p/nk-9020k-v.htm (дата обращения: 01.04.2014).</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>6.	Rekha B. B., Kandaswamy A., Keerthana R.A. Artificial Intelligence Based Automated Estimation of Sleep Stages Using Electrocardiograph Signals: A Perspective // Applied Mechanics and Materials. – 2014. – No. 573/9.– pp. 836 – 841</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>7.	Tancheng L., Peng L., Xiang G., Qiyong L. A Portable ECG Monitor with Low Power Consumption and Small Size Based on AD8232 Chip // Applied Mechanics and Materials. – 2014. – No. 513/3.– pp. 2884 – 2887</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>8.	Ying-Chieh W., Ying-Yu W., Shaang-Tzuu W., Ling-Sheng J. Design of a Programmable ECG Generator Using a Dynamical Model // Applied Mechanics and Materials. – 2013. – No. 311/8.– pp. 485 – 490</p>
        </note>
      </ref>
    </ref-list>